NOT just another flavor separation

Thursday, August 13th, 2009

On a rainy fourth of July weekend, my brother Sam and I were hard at work in the lab working on our latest project. CCC flavor separation.  Admittedly, we were not happy about missing out on bbq, beer and fireworks, but we were both excited about getting this project started. Our ultimate goal? To put the power of flavor separation in the hands of chefs, which is a power that is now largely restricted to flavor houses.

It  started a few weeks earlier. As I was impatiently waiting in outbound Chicago traffic, on my way home for the weekend, I get a call from Sam.  He wanted to talk with me an idea he had about using CCC for flavor separation.  In the kitchen CCC could be used to separate complex flavors into groups of flavor constituents.  A chef with the right CCC instrument and a grasp of the basic concepts could use the technology to either to isolate desired flavors from a mix or remove an undesirable flavor. It sounded great to me. I love food and I’m always game for fun and offbeat projects like this.

Despite many hours logged watching food network, I didn’t know enough about the culinary world to understand how CCC could fit into a kitchen.  I needed to consult and expert. Alton Brown came to mind, but since I didn’t think he’d be particularly easy to get in touch with I decided to call around to talk with some local chefs.  Many calls later with little progress I went to the net to look for culinary folks who were into integrating cool new technology into to kitchen. Enter Dave Arnold.

Food hacker and director of culinary tech at the French Culinary Institute

Food hacker and director of culinary tech at the French Culinary Institute

After talking to Dave Arnold, the director of culinary technology at the French Culinary Institute, I finally felt that I’d found the connection to the inside culinary knowledge that was required for the project.  Dave told me he spends the majority of his day thinking about new ways to tweak flavors. I knew I was talking to the right guy.

After telling Dave about Sam’s CCC flavor separation idea it was time to take this project to the next level.  Sam and I were on a mission to prove that flavor separation on CCC was feasible in a kitchen, which meant we needed a food safe solvent system and proof that it was easy enough to be a practical tool for a chef.

The first step was to design a solvent system that is food safe. It was fairly obvious where we needed to go for food safe supplies… the grocery store! We bought a variety of oils, distilled water and everclear.

A variety of oils and everclear (distilled water not shown)

A variety of oils and everclear (distilled water not shown)

For our solvent system to have any hope of working we needed the system to have a decent settling time. So we spent hours and hours mixing water, alcohol and different oils. Then we shook up all of our prospective systems and timed how long it took for them to separate.

Glass vials fill of prospective food safe solvent systems

Glass vials fill of prospective food safe solvent systems

Our solvent system evaluations lead us to adopt everclear and canola oil for our first attemts at flavor separation.

With our solvent system in place we needed some food samples to try out.

Find what our friends at the French Culinary Institute though of our preliminary flavor separation as the story continues on Dave Arnold’s blog see “Just another flavor separation technique

PREP 2009 update!

Friday, June 12th, 2009

I am happy to announce that Cherry Instruments will be exhibiting at PREP 2009 on July 19th through the 21st.  We are excited to participate. PREP is an international symposium, exhibit and workshop on Preparative and Process Chromatography.

PREP 2009 will be taking place at the Loews Hotel in Philadelphia. We will be at booth #31. For more information go to www.PREPSYMPOSIUM.org or contact us.

CCC does reference standards

Friday, June 12th, 2009

Tauto Biotech, our Chinese friends and producers of our line of type J instruments, have been using CCC to make quality reference standards for many years.  In fact, our entire line of reference standards are produced by Tauto Biotech HSCCC instruments.

I recently asked Jack Jiang, a Tauto employee, about Tauto’s experience using CCC to produce reference standards.

1) How does the production of reference standards using HSCCC benefit
Tauto Biotech and how did it all start?
Since the year 1999 when Tauto was founded, the company has been devoting efforts on the development of the chemical database of natural monomers and the separation work of botanical reference materials by HSCCC. The separation with HSCCC technology can prove the efficiency of active components separation with the related HSCCC equipment, while it can also get the wanted active components with high purity and low cost.

2) Why use CCC rather than other techniques such as HPLC to produce
reference standards?

Based upon the features of CCC, it has its own advantages in separation of reference materials:
large injection volume, high resolution, high yield rate, good reproducibility,easy to scale-up, low cost in production, no consumption of consumables, low maintenance fee.

3) Are there any instances where HSCCC was particularly useful for
producing reference standards? (for example where the purity is
superior or where reference standards can be produce much more
efficiently?

Instance: Separation of Ginkgolide J, Huperzine B, Isomers of Gambogic Acid

4) What are the most important things to know for someone who is
considering adopting the use of HSCCC for the production of reference
standards?
a. Check the characteristics of the sample to see whether it is suitable for the separation by CCC.

b. The most important technology point is the selection of solvent system for HSCCC separation

CCC Education

Friday, May 8th, 2009

Dr Chadwick and I have been preparing material for two online presentations. Next Thursday the 14th we will present “Introduction to Countercurrent Chromatography,” at noon and “Choosing CCC Solvent Systems,” at one.   Both webinars will consist of thirty minute presentations, after which Dr. Chadwick will be available for questions. If you are interested please send me an e-mail.

CCC developments in Hangzhou China

Wednesday, April 29th, 2009

View Larger Map
There’s been a lot of CCC activity at Zheijiang University in Hangzhou China. Recently, a group from the chemistry department described a comparison of elution-extrusion CCC (EECCC) and back-extrusion CCC (BECCC).

In both EECCC and BECCC the columns are first filled with upper phase, which is the stationary phase for the first part of the run. The lower phase, which is also the mobile phase is now pumped through the column.  The compounds with the highest affinity for the mobile phase are eluted first, however, some compounds with higher affinities for the stationary phase remain in the column.  The compounds still present in the stationary phase may be separated, but would required wasteful amounts of mobile phase to be eluted. EECCC, avoids wasting time and mobile phase by extruding the stationary phase with one column volume of upper phase.  The stationary phase is fractionated during the extrusion process.

In BECCC the elution step is exactly the same, however the flow direction is changed for the extrusion step and mobile phase is pumped into the column rather than stationary phase.   EECCC is more amenable to high-throughput fractionation because each injection cycle begins and ends in the same state (filled with upper phase).  In BECCC, each injection cycle ends with the column filled with the opposite phase as the previous cycle.  One advantage to BECCC is that it avoids producing a large surplus of one phase over another, but otherwise I doesn’t see much use in our lab.

An original Ito apparatus “a coil planet centrifuge with one 140-mL coil and a counter-weight” was used for the both the EECCC and the BECCC experiments.  My first CCC separation was on an Ito apparatus which was what got me “hooked,” on CCC in the first place. The column I learned CCC on, now 25 years old, is still fully operational! If well cared-for, CCC columns can have a virtually endless life.  For solvent system selection, they describe the use of an “analytical-scale integrated parallel CCC separation system manufactured by the Zhejiang University machine shop”.  The column has three parallel 40 ml columns.

Earlier this year another research group from Zheijiang U, in the Research Center of Siyuan Natural Pharmacy and Biotoxicology Department, reported their efforts to develop a “new multichannel CCC method and apparatus for the high-throughput fractionation of natural products for drug discovery.” Their method makes use of a single CCC solvent system (hexane:ethanol:water 6:5:1) for all investigated samples (all of which were crude defatted EtOAc extracts), followed by purification of active fractions with preparative HPLC.  The authors state that this regime was developed as a response to the intrinsic challenges of determining an ideal solvent system for any given target compound.  Also, they note that the shorter CCC columns provide lower resolution than what is obtained with a comparable single-channel instrument. Innovative features of the apparatus include temperature control from 20-60C and three independent 300 ml columns, each with separate dedicated pump, detector, and fraction collector.   They note that senior engineer Yucheng Wu, who is not listed as an author, fabricated the instrument at Zheijiang U.

The authors provide a succinct review of high-throughput purification methods for natural product compound libraries and summarize with the following quote:  “These throughput purification techniques mentioned above, including FC, HPLC and SFC, are revolutionizing the process of natural product discovery and provide high-quality compounds or compound mixtures for biological screening. However, these techniques always use a solid support matrix, resulting in irreversible adsorptive sample loss and deactivation, tailing of solute peaks, and contamination.”

The authors conclude with “it is essential to take into account of the lower resolution compromise for the fabrication of new multi-channel CCC devices in the future.”

We find the technology quite promising, particularly if efforts to develop regimes of orthogonal CCC solvent systems are incorporated into their method (e.g. following Brent Friesen’s work on solvent system families).  Use of solid adsorbents in a sense defeats the stated purpose of avoiding absorptive loss, deactivation and contamination.